Design
The design of MC Flow Meters meets Worldwide Weights and Measures Standards. Inside the meter housing, a small number of moving parts along with no metal to metal contact, ensures quiet and smooth operation and provides low and easy maintenance.
Features
- Lack of internal friction (No metal-to-metal contact)
- Reduced number of parts
- Long lifetime
- Low and easy maintenance
- Self-lubricating
- Low drop pressure between parts
- Simple and robust design
- Bi-directional liquid flow
- Meets Worldwide Weights and Measures Standards
- Repeatability under diverse condititions and products
- Continuous Accuracy over a wide range of liquids and transfer conditions
Specifications
- Materials of Construction: Aluminum,Cast iron
- Size: Available in 1 ½” to 6” sizes
- Flow rate: 25lpm to 3000 lpm (7 gpm to 800 gpm)
- Viscosity: up to 1,500,00 SSU
- Temperature: -40 to +71°C (- 40 to +160°F)
- Working pressure: 10 bar (150psi)
- Flanges: ANSI, NPT, BSPT threads
- Seal Materials: Buna-N, Viton, Teflon
- Certification: ATEX, MID, ISO
Repeatability:
- - Capable of 0,05% of reading over entire range of flow rate with mechanical counter
- - Capable of 0,02% of reading over entire range of flow rate with electronic register
Accuracy:
- Over 5:1 range
- - Capable of achieving an accuracy better than ±0,125% of maximum nominal flow rate with mechanical counter
- - Capable of achieving an accuracy better than ±0,1% of maximum nominal flow rate with electronic register
- Over 10:1 range
- - Capable of achieving an accuracy better than ±0,22% of maximum nominal flow rate with mechanical counter
- - Capable of achieving an accuracy better than ±0,1% of maximum nominal flow rate with electronic register
- Over 40:1 range
- - Capable of achieving an accuracy better than ±0,3% of maximum nominal flow rate with mechanical counter
- - Capable of achieving an accuracy better than ±0,15% of maximum nominal flow rate with electronic register
Capable of achieving an accuracy better than +/-0,1 % for known transfer conditions (fluid, viscosity and range of flow rate).
Flow Meters should be calibrated on a basis appropriate to the conditions of their operating environment. Many types are sensitive to the viscosity of the operating fluid, some deliver unusual outputs, others have control mechanisms built into their outputs or displays.
MC Series Flow Meters |
Connection size |
Flow Rate lpm (gpm) |
MC505 |
1 ½" (optional 2") |
25 – 250 (7 -70) |
MC507 |
2" |
50 – 500 (13 -130) |
MC515 |
3" |
75 – 750 (20 -200) |
MC525 |
3" |
115 – 1150 (30 -300) |
MC530 |
4" |
130 – 1300 (35 -350) |
MC540 |
4" |
170 – 1700 (45 -450) |
MC560 |
6" (optional 4") |
225 – 2250 (60 -600) |
MC580 |
6" |
300 – 3000 (80 -800) |
Any Query ?